Specifications and Features
Copyright
2001 Phone: (614) 771-2718 RE-ACM
Vanner Inc. FAX: 614-771-4904 Owners/Installation Manual
4282 Reynolds Dr. www.vanner.com Rev 0.1a
Hilliard Ohio 43026 RE-ACM-Owners_Man_R01a.doc
7
INCORPORATED
INCORPORATEDINCORPORATED
INCORPORATED
T 1 Table 2.0-1 RE-ACM AC Control Module Specifications
AC Power Output
Rated Output Watts (-40 to +40°C) 4500 Watts
Continuous Output at 25°C (77°F) 4500 Watts
Continuous Output at 40°C (104°F) 3650 Watts
Max Continuous Output on L1 or L2 26.5 Amps (Electronically current limited by
RE-4500)
3 Second Surge Output (at 24 VDC input, and 25ºC) 10000 VA
AC Maximum Output Fault Current 56.25 Arms
(Inverter shuts down in 1/60 sec)
Output Voltage, Single Phase, 3 Wire 120/240 Vrms \
Output Frequency 60 Hz
AC Output Wiring Method Hardwire Terminal Strip
AC Transfer Switch
Amperage Rating 30 Amp 240 Volt
Output Neutral to Ground Not Bonded
System
Generator Start & Low Battery Warning Control Relays Rating 5 Amps 120 VAC / 12VDC / 24 VDC
(Resistive load)
Ambient Operating Temperature -40° to +40°C (-40 to +104°F)
Enclosure Painted Aluminum for Wall Mounting
Dimensions TBD H x TBD W x 9¼ D
Unit Weight TBD pounds